Retrieves the length of the value associated with a key 
<H2>Synopsis</H2>
<PRE>
#undef FUNCNAME
#define FUNCNAME MPIRInfo_get_valuelen
#undef FCNAME
#define FCNAME MPL_QUOTE(FUNCNAME)
int MPI_Info_get_valuelen(MPI_Info info, const char *key, int *valuelen, int *flag)
</PRE>
<H2>Input Parameters</H2>
<DL>
<DT><B>info </B> <DD> info object (handle)

<DT><B>key </B> <DD> key (string)
</DL>
<P>
<H2>Output Parameters</H2>
<DL>
<DT><B>valuelen </B> <DD> length of value argument (integer)

<DT><B>flag </B> <DD> true if key defined, false if not (boolean)
</DL>
<P>
<P>
<H2>Thread and Interrupt Safety</H2>
<P>
This routine is thread and interrupt safe only if no MPI routine that
updates or frees the same <tt>MPI_Info</tt> object may be called concurrently
with this routine.
<P>
The MPI standard defined a thread-safe interface but this does not
mean that all routines may be called without any thread locks.  For
example, two threads must not attempt to change the contents of the
same <tt>MPI_Info</tt> object concurrently.  The user is responsible in this
case for using some mechanism, such as thread locks, to ensure that
only one thread at a time makes use of this routine.
<P>
<H2>Notes for Fortran</H2>
All MPI routines in Fortran (except for <tt>MPI_WTIME</tt> and <tt>MPI_WTICK</tt>) have
an additional argument <tt>ierr</tt> at the end of the argument list.  <tt>ierr
</tt>is an integer and has the same meaning as the return value of the routine
in C.  In Fortran, MPI routines are subroutines, and are invoked with the
<tt>call</tt> statement.
<P>
All MPI objects (e.g., <tt>MPI_Datatype</tt>, <tt>MPI_Comm</tt>) are of type <tt>INTEGER
</tt>in Fortran.
<P>
<H2>Errors</H2>
<P>
All MPI routines (except <tt>MPI_Wtime</tt> and <tt>MPI_Wtick</tt>) return an error value;
C routines as the value of the function and Fortran routines in the last
argument.  Before the value is returned, the current MPI error handler is
called.  By default, this error handler aborts the MPI job.  The error handler
may be changed with <tt>MPI_Comm_set_errhandler</tt> (for communicators),
<tt>MPI_File_set_errhandler</tt> (for files), and <tt>MPI_Win_set_errhandler</tt> (for
RMA windows).  The MPI-1 routine <tt>MPI_Errhandler_set</tt> may be used but
its use is deprecated.  The predefined error handler
<tt>MPI_ERRORS_RETURN</tt> may be used to cause error values to be returned.
Note that MPI does <em>not</em> guarentee that an MPI program can continue past
an error; however, MPI implementations will attempt to continue whenever
possible.
<P>
<DL>
<DT><B>MPI_SUCCESS </B> <DD> No error; MPI routine completed successfully.
</DL>
<P>
<DL>
<DT><B>MPI_ERR_INFO_KEY </B> <DD> Invalid or null key string for info.
</DL>
<DL>
<DT><B>MPI_ERR_OTHER </B> <DD> Other error; use <tt>MPI_Error_string</tt> to get more information
about this error code. 
</DL>
</BODY></HTML>