# Configuration file contributed by Balint Szente.
# Intel D2500CC based on BIOS values
#
chip "w83627uhg-*"
ignore intrusion0
# Voltages
# Processor Vcc
label in0 "Vcore"
set in0_min 0.91 * 0.99
set in0_max 1.21 * 1.01
# +3.3V
label in1 "+3.3V"
compute in1 3.2*@, @/3.2
set in1_min 3.3 * 0.95
set in1_max 3.3 * 1.05
# +5.0V
label in3 "+5V"
set in3_min 5.0 * 0.95
set in3_max 5.0 * 1.05
# +12.0V
label in4 "+12V"
compute in4 12*@, @/12
set in4_min 12 * 0.95
set in4_max 12 * 1.05
# Memory Vcc
label in5 "Vdimm"
set in5_min 1.5 * 0.95
set in5_max 1.5 * 1.05
# +5.0V Standby
label in7 "5VSB"
set in7_min 4.60
set in7_max 5.40
# Fans
label fan1 "System Fan"
set fan1_min 250
ignore fan2
# Temperatures
# Memory Temperature
label temp1 "DIMM temp"
set temp1_max 80
set temp1_max_hyst 75
# VR Temperature
label temp2 "VR temp"
set temp2_max 80
set temp2_max_hyst 75