Blob Blame History Raw
RFC1382-MIB DEFINITIONS ::= BEGIN

IMPORTS
        Counter, Gauge, TimeTicks
                FROM RFC1155-SMI
        OBJECT-TYPE
                FROM RFC-1212
        DisplayString, transmission
                FROM RFC1213-MIB
        TRAP-TYPE
                FROM RFC-1215
        EntryStatus
                FROM RFC1271-MIB
        PositiveInteger,
        IfIndexType
                FROM RFC1381-MIB;

x25     OBJECT IDENTIFIER ::= { transmission 5 }


-- Support of the X25 subtree and all subtrees under it
-- is mandatory for all agents of system that implement X.25.

X121Address ::= OCTET STRING (SIZE(0..17))
 -- 0 to 17 bytes in length containing the ASCII
 -- characters [0-9], each octet contains one digit
 -- of the address.


-- ###########################################################
--            X.25 Administration Table
-- ###########################################################

x25AdmnTable OBJECT-TYPE
        SYNTAX  SEQUENCE OF X25AdmnEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                "This table contains the administratively
                set configuration parameters for an X.25
                Packet Level Entity (PLE).

               Most of the objects in this table have
                corresponding objects in the x25OperTable.
                This table contains the values as last set
                by the administrator.  The x25OperTable
                contains the values actually in use by an
                X.25 PLE.

                Changing an administrative value may or may
                not change a current operating value.  The
                operating value may not change until the
                interface is restarted.  Some
                implementations may change the values
                immediately upon changing the administrative
                table.  All implementations are required to
                load the values from the administrative
                table when initializing a PLE."
        ::= { x25 1 }

x25AdmnEntry OBJECT-TYPE
        SYNTAX  X25AdmnEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                "Entries of x25AdmnTable."
        INDEX { x25AdmnIndex }
        ::= { x25AdmnTable 1 }

X25AdmnEntry ::= SEQUENCE {
        x25AdmnIndex
                IfIndexType,
        x25AdmnInterfaceMode
                INTEGER,
        x25AdmnMaxActiveCircuits
                INTEGER,
        x25AdmnPacketSequencing
                INTEGER,
        x25AdmnRestartTimer
                PositiveInteger,
     x25AdmnCallTimer
                PositiveInteger,
        x25AdmnResetTimer
                PositiveInteger,
        x25AdmnClearTimer
                PositiveInteger,
        x25AdmnWindowTimer
                PositiveInteger,
        x25AdmnDataRxmtTimer
                PositiveInteger,
        x25AdmnInterruptTimer
                PositiveInteger,
        x25AdmnRejectTimer
                PositiveInteger,
        x25AdmnRegistrationRequestTimer
                PositiveInteger,
        x25AdmnMinimumRecallTimer
                PositiveInteger,
        x25AdmnRestartCount
                INTEGER,
        x25AdmnResetCount
                INTEGER,
        x25AdmnClearCount
                INTEGER,
        x25AdmnDataRxmtCount
                INTEGER,
        x25AdmnRejectCount
                INTEGER,
        x25AdmnRegistrationRequestCount
                INTEGER,
        x25AdmnNumberPVCs
                INTEGER,
        x25AdmnDefCallParamId
                OBJECT IDENTIFIER,
        x25AdmnLocalAddress
                X121Address,
        x25AdmnProtocolVersionSupported
                OBJECT IDENTIFIER
        }

x25AdmnIndex OBJECT-TYPE
        SYNTAX  IfIndexType
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
        "The ifIndex value for the X.25 Interface."
        ::= { x25AdmnEntry 1 }

x25AdmnInterfaceMode OBJECT-TYPE
        SYNTAX  INTEGER {
                        dte (1),
                        dce (2),
                        dxe (3)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Identifies DCE/DTE mode in which the
                interface operates.  A value of dxe
                indicates the mode will be determined by XID
                negotiation."
        REFERENCE "10733 5.9 interfaceMode"
        ::= { x25AdmnEntry 2 }

x25AdmnMaxActiveCircuits        OBJECT-TYPE
        SYNTAX  INTEGER (0..4096)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The maximum number of circuits this PLE can
                support; including PVCs."
        REFERENCE "10733 5.9 maxActiveCircuits;
                See ISO 8208, Section 3.7"
        ::= { x25AdmnEntry 3 }

x25AdmnPacketSequencing OBJECT-TYPE
        SYNTAX  INTEGER {
                        modulo8 (1),
                        modulo128 (2)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The modulus of the packet sequence number
                space."
        REFERENCE "10733 extendedPacketSequencing;
                See ISO 8208 Section 7.1.1"
        ::= { x25AdmnEntry 4 }

x25AdmnRestartTimer OBJECT-TYPE
     SYNTAX     PositiveInteger
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The T20 restart timer in milliseconds."
        REFERENCE "10733 5.9 restartTime
                See ISO 8208 Section 4.1, table 26"
        ::= { x25AdmnEntry 5 }

x25AdmnCallTimer OBJECT-TYPE
        SYNTAX  PositiveInteger
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The T21 Call timer in milliseconds."
        REFERENCE "10733 callTime;
                See ISO 8208 Section 5.2.1, table 26"
        ::= { x25AdmnEntry 6 }

x25AdmnResetTimer OBJECT-TYPE
        SYNTAX  PositiveInteger
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The T22 Reset timer in milliseconds."
        REFERENCE "10733 resetTime;
                See ISO 8208 Section 8.1, table 26"
        ::= { x25AdmnEntry 7 }

x25AdmnClearTimer OBJECT-TYPE
        SYNTAX  PositiveInteger
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The T23 Clear timer in milliseconds."
        REFERENCE "10733 clearTime;
                See ISO 8208 Section 5.5.1, table 26"
        ::= { x25AdmnEntry 8 }

x25AdmnWindowTimer OBJECT-TYPE
        SYNTAX  PositiveInteger
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The T24 window status transmission timer in
                milliseconds.  A value of 2147483647
                indicates no window timer in use."
        REFERENCE "10733 5.10.1 windowTime (opt);
                See ISO 8208 Section 11.2.2, table 26"
        ::= { x25AdmnEntry 9 }

x25AdmnDataRxmtTimer OBJECT-TYPE
        SYNTAX  PositiveInteger
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The T25 data retransmission timer in
                milliseconds.  A value of 2147483647
                indicates no data retransmission timer in
                use."
        REFERENCE "10733 5.10.1 dataRetransmissionTime (opt);
                See ISO 8208 Section 11.2.1, table 26"
        ::= { x25AdmnEntry 10 }

x25AdmnInterruptTimer OBJECT-TYPE
        SYNTAX  PositiveInteger
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The T26 interrupt timer in milliseconds.  A
                value of 2147483647 indicates no interrupt
                timer in use."
        REFERENCE "10733 interruptTime;
                See ISO 8208 Section 6.8.1, table 26"
        ::= { x25AdmnEntry 11 }

x25AdmnRejectTimer OBJECT-TYPE
        SYNTAX  PositiveInteger
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The T27 Reject retransmission timer in
                milliseconds.  A value of 2147483647
                indicates no reject timer in use."
        REFERENCE "10733 5.10.1 dataRejectTime (opt);
                See ISO 8208 Section 13.4.1, table 26"
        ::= { x25AdmnEntry 12 }

x25AdmnRegistrationRequestTimer OBJECT-TYPE
        SYNTAX  PositiveInteger
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The T28 registration timer in milliseconds.
                A value of 2147483647 indicates no
                registration timer in use."
        REFERENCE "10733 5.8.1 registrationRequestTime (opt)
                See ISO 8208    Section 13.1.1.1, table 26"
        ::= { x25AdmnEntry 13 }

x25AdmnMinimumRecallTimer OBJECT-TYPE
        SYNTAX  PositiveInteger
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Minimum time interval between unsuccessful
                call attempts in milliseconds."
        REFERENCE "10733 5.9 minimum RecallTimer"
        ::= { x25AdmnEntry 14 }

x25AdmnRestartCount OBJECT-TYPE
        SYNTAX  INTEGER (0..65535)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The R20 restart retransmission count."
        REFERENCE "10733 5.9 restartCount;
                See ISO 8208    Section 4.1, table 27"
        ::= { x25AdmnEntry 15 }

x25AdmnResetCount OBJECT-TYPE
        SYNTAX  INTEGER (0..65535)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The r22 Reset retransmission count."
        REFERENCE "10733 resetCount;
                See section ISO 8208 8.1, table 27"
        ::= { x25AdmnEntry 16 }

x25AdmnClearCount OBJECT-TYPE
        SYNTAX  INTEGER (0..65535)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
        "The r23 Clear retransmission count."
        REFERENCE "10733 clearCount;
                See ISO 8208 Section 5.5.1, table 27"
        ::= { x25AdmnEntry 17 }

x25AdmnDataRxmtCount OBJECT-TYPE
        SYNTAX  INTEGER (0..65535)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The R25 Data retransmission count.  This
                value is irrelevant if the
                x25AdmnDataRxmtTimer indicates no timer in
                use."
        REFERENCE "10733 5.10.1 dataRetransmissionCount (opt)
                See ISO 8208 Section 11.2.1, table 27"
        ::= { x25AdmnEntry 18 }

x25AdmnRejectCount OBJECT-TYPE
        SYNTAX  INTEGER (0..65535)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The R27 reject retransmission count.  This
                value is irrelevant if the
                x25AdmnRejectTimer indicates no timer in
                use."
        REFERENCE "10733 5.10.1 dataRejectCount (opt)"
        ::= { x25AdmnEntry 19 }

x25AdmnRegistrationRequestCount OBJECT-TYPE
        SYNTAX  INTEGER (0..65535)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The R28 Registration retransmission Count.
                This value is irrelevant if the
                x25AdmnRegistrationRequestTimer indicates no
                timer in use."
        REFERENCE "10733 5.8.1 registrationRequestCount (opt);
                See ISO 8208    Section 13.1.1.1, table 27"
        ::= { x25AdmnEntry 20 }

x25AdmnNumberPVCs OBJECT-TYPE
        SYNTAX  INTEGER (0..4096)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The number of PVC configured for this PLE.
                The PVCs use channel numbers from 1 to this
                number."
        ::= { x25AdmnEntry 21 }

x25AdmnDefCallParamId OBJECT-TYPE
        SYNTAX  OBJECT IDENTIFIER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "This identifies the instance of the
                x25CallParmIndex for the entry in the
                x25CallParmTable which contains the default
                call parameters for this PLE."
        ::= { x25AdmnEntry 22 }

x25AdmnLocalAddress OBJECT-TYPE
        SYNTAX  X121Address
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The local address for this PLE subnetwork.
                A zero length address maybe returned by PLEs
                that only support PVCs."
        REFERENCE "10733 5.9 localDTEAddress"
        ::= { x25AdmnEntry 23 }

x25AdmnProtocolVersionSupported OBJECT-TYPE
        SYNTAX  OBJECT IDENTIFIER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Identifies the version of the X.25 protocol
                this interface should support.  Object
                identifiers for common versions are defined
                below in the x25ProtocolVersion subtree."
        REFERENCE "10733 5.9 protocolVersionSupported"
        ::= { x25AdmnEntry 24 }


-- ###########################################################
--            X.25 Operational Table
-- ###########################################################

x25OperTable OBJECT-TYPE
        SYNTAX  SEQUENCE OF X25OperEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                "The operation parameters in use by the X.25
                PLE."
        ::= { x25 2 }

x25OperEntry OBJECT-TYPE
        SYNTAX  X25OperEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                "Entries of x25OperTable."
        INDEX { x25OperIndex }
        ::= { x25OperTable 1 }

X25OperEntry ::= SEQUENCE {
        x25OperIndex
                IfIndexType,
        x25OperInterfaceMode
                INTEGER,
        x25OperMaxActiveCircuits
                INTEGER,
        x25OperPacketSequencing
                INTEGER,
        x25OperRestartTimer
                PositiveInteger,
        x25OperCallTimer
                PositiveInteger,
        x25OperResetTimer
                PositiveInteger,
        x25OperClearTimer
                PositiveInteger,
        x25OperWindowTimer
                PositiveInteger,
        x25OperDataRxmtTimer
                PositiveInteger,
        x25OperInterruptTimer
                PositiveInteger,
        x25OperRejectTimer
                PositiveInteger,
     x25OperRegistrationRequestTimer
                PositiveInteger,
        x25OperMinimumRecallTimer
                PositiveInteger,
        x25OperRestartCount
                INTEGER,
        x25OperResetCount
                INTEGER,
        x25OperClearCount
                INTEGER,
        x25OperDataRxmtCount
                INTEGER,
        x25OperRejectCount
                INTEGER,
        x25OperRegistrationRequestCount
                INTEGER,
        x25OperNumberPVCs
                INTEGER,
        x25OperDefCallParamId
                OBJECT IDENTIFIER,
        x25OperLocalAddress
                X121Address,
        x25OperDataLinkId
                OBJECT IDENTIFIER,
        x25OperProtocolVersionSupported
                OBJECT IDENTIFIER
        }

x25OperIndex OBJECT-TYPE
        SYNTAX  IfIndexType
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The ifIndex value for the X.25 interface."
        ::= { x25OperEntry 1 }

x25OperInterfaceMode OBJECT-TYPE
        SYNTAX  INTEGER {
                        dte (1),
                        dce (2),
                        dxe (3)
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
        "Identifies DCE/DTE mode in which the
                interface operates.  A value of dxe
                indicates the role will be determined by XID
                negotiation at the Link Layer and that
                negotiation has not yet taken place."
        REFERENCE "10733 5.9 interfaceMode"
        ::= { x25OperEntry 2 }

x25OperMaxActiveCircuits        OBJECT-TYPE
        SYNTAX  INTEGER (0..4096)
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Maximum number of circuits this PLE can
                support."
        REFERENCE "10733 5.9 maxActiveCircuits
                See ISO 8208, Section 3.7"
        ::= { x25OperEntry 3 }

x25OperPacketSequencing OBJECT-TYPE
        SYNTAX  INTEGER {
                        modulo8 (1),
                        modulo128 (2)
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The modulus of the packet sequence number
                space."
        REFERENCE "10733 extendedPacketSequencing;
                See ISO 8208    Section 7.1.1"
        ::= { x25OperEntry 4 }

x25OperRestartTimer OBJECT-TYPE
        SYNTAX  PositiveInteger
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The T20 restart timer in milliseconds."
        REFERENCE "10733 5.9 restartTime;
                See ISO 8208    Section 4.1, table 26"
        ::= { x25OperEntry 5 }

x25OperCallTimer OBJECT-TYPE
        SYNTAX  PositiveInteger
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The T21 Call timer in milliseconds."
        REFERENCE "10733 callTime;
                See ISO 8208 Section 5.2.1, table 26"
        ::= { x25OperEntry 6 }

x25OperResetTimer OBJECT-TYPE
        SYNTAX  PositiveInteger
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The T22 Reset timer in milliseconds."
        REFERENCE "10733 resetTime;
                See ISO 8208    Section 8.1, table 26"
        ::= { x25OperEntry 7 }

x25OperClearTimer OBJECT-TYPE
        SYNTAX  PositiveInteger
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The T23 Clear timer in milliseconds."
        REFERENCE "10733 clearTime;
                See ISO 8208 Section 5.5.1, table 26"
        ::= { x25OperEntry 8 }

x25OperWindowTimer OBJECT-TYPE
        SYNTAX  PositiveInteger
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The T24 window status transmission timer
                milliseconds.  A value of 2147483647
                indicates no window timer in use."
        REFERENCE "10733 5.10.1 windowTime (opt);
                See ISO 8208 Section 11.2.2, table 26"
        ::= { x25OperEntry 9 }

x25OperDataRxmtTimer OBJECT-TYPE
        SYNTAX  PositiveInteger
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The T25 Data Retransmission timer in
                milliseconds.  A value of 2147483647
                indicates no data retransmission timer in
                use."
        REFERENCE "10733 5.10.1 dataRetransmissionTime (opt);
                See ISO 8208 Section 11.2.1, table 26"
        ::= { x25OperEntry 10 }

x25OperInterruptTimer OBJECT-TYPE
        SYNTAX  PositiveInteger
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The T26 Interrupt timer in milliseconds.  A
                value of 2147483647 indicates interrupts are
                not being used."
        REFERENCE "10733 interruptTime;
                See ISO 8208 Section 6.8.1, table 26"
        ::= { x25OperEntry 11 }

x25OperRejectTimer OBJECT-TYPE
        SYNTAX  PositiveInteger
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The T27 Reject retransmission timer in
                milliseconds.  A value of 2147483647
                indicates no reject timer in use."
        REFERENCE "10733 5.10.1 dataRejectTime (opt);
                See ISO 8208 Section 13.4.1, table 26"
        ::= { x25OperEntry 12 }

x25OperRegistrationRequestTimer OBJECT-TYPE
        SYNTAX  PositiveInteger
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The T28 registration timer in milliseconds.
                A value of 2147483647 indicates no
                registration timer in use."
        REFERENCE "10733 5.8.1 registrationRequestTime (opt);
                See ISO 8208    Section 13.1.1.1, table 26"
        ::= { x25OperEntry 13 }

x25OperMinimumRecallTimer OBJECT-TYPE
        SYNTAX  PositiveInteger
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Minimum time interval between unsuccessful
                call attempts in milliseconds."
        REFERENCE "10733 5.9 minimum RecallTimer"
        ::= { x25OperEntry 14 }

x25OperRestartCount OBJECT-TYPE
        SYNTAX  INTEGER (0..65535)
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The R20 restart retransmission count."
        REFERENCE "10733 5.9 restartCount
                See ISO 8208    Section 4.1, table 27"
        ::= { x25OperEntry 15 }

x25OperResetCount OBJECT-TYPE
        SYNTAX  INTEGER (0..65535)
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The r22 Reset retransmission count."
        REFERENCE "10733 resetCount;
                See section ISO 8208 8.1, table 27"
        ::= { x25OperEntry 16 }

x25OperClearCount OBJECT-TYPE
        SYNTAX  INTEGER (0..65535)
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The r23 Clear retransmission count."
        REFERENCE "10733 clearCount;
                See ISO 8208 Section 5.5.1, table 27"
        ::= { x25OperEntry 17 }

x25OperDataRxmtCount OBJECT-TYPE
        SYNTAX  INTEGER (0..65535)
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The R25 Data retransmission count.  This
                value is undefined if the
                x25OperDataRxmtTimer indicates no timer in
                use."
        REFERENCE "10733 5.10.1 dataRetransmissionCount (opt);
                See ISO 8208 Section 11.2.1, table 27"
        ::= { x25OperEntry 18 }

x25OperRejectCount OBJECT-TYPE
        SYNTAX  INTEGER (0..65535)
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The R27 reject retransmission count.  This
                value is undefined if the x25OperRejectTimer
                indicates no timer in use."
        REFERENCE "10733 5.10.1 dataRejectCount (opt)"
        ::= { x25OperEntry 19 }

x25OperRegistrationRequestCount OBJECT-TYPE
        SYNTAX  INTEGER (0..65535)
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The R28 Registration retransmission Count.
                This value is undefined if the
                x25OperREgistrationRequestTimer indicates no
                timer in use."
        REFERENCE "10733 5.8.1 registrationRequestCount (opt);
                See ISO 8208    Section 13.1.1.1, table 27"
        ::= { x25OperEntry 20 }

x25OperNumberPVCs OBJECT-TYPE
        SYNTAX  INTEGER (0..4096)
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The number of PVC configured for this PLE.
                The PVCs use channel numbers from 1 to this
                number."
        ::= { x25OperEntry 21 }

x25OperDefCallParamId OBJECT-TYPE
        SYNTAX  OBJECT IDENTIFIER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "This identifies the instance of the
                x25CallParmIndex for the entry in the
                x25CallParmTable that contains the default
                call parameters for this PLE."
        ::= { x25OperEntry 22 }

x25OperLocalAddress OBJECT-TYPE
        SYNTAX  X121Address
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The local address for this PLE subnetwork.
                A zero length address maybe returned by PLEs
                that only support PVCs."
        REFERENCE "10733 5.9 localDTEAddress"
        ::= { x25OperEntry 23 }

x25OperDataLinkId OBJECT-TYPE
        SYNTAX  OBJECT IDENTIFIER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "This identifies the instance of the index
                object in the first table of the most device
                specific MIB for the interface used by this
                PLE."
        ::= { x25OperEntry 24 }

x25OperProtocolVersionSupported OBJECT-TYPE
        SYNTAX  OBJECT IDENTIFIER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Identifies the version of the X.25 protocol
                this interface supports.  Object identifiers
                for common versions are defined below in the
                x25ProtocolVersion subtree."
        REFERENCE "10733 5.9 protocolVersionSupported"
        ::= { x25OperEntry 25 }


--      MIB-II also provides:

-- ifDescr:
-- On an X.25 interface this must include sufficient

-- information to enable the system's administrator
-- to determine the appropriate configuration
-- information on a system having multiple X.25
-- subnetworks.

-- ifType: ddn-x25 or rfc877-x25
--      an interface of type ddn-x25 will use an algorithm to
--      translate between X.121 address and IP addresses.
--      An interface of type rfc877-x25 will use a
--      configuration table to translate between X.121
--      addresses and IP addresses.

-- ifMtu: the maximum PDU a higher layer can pass to X.25 or
-- receive from X.25

-- ifSpeed:
-- This will be the value of the local clock for this line.
-- A value of zero indicates external clocking.

-- ifAdminStatus:

-- ifOperStatus

-- ifLastChange


-- ###########################################################
--            X.25 Statistics Table
-- ###########################################################

x25StatTable OBJECT-TYPE
        SYNTAX  SEQUENCE OF X25StatEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                "Statistics information about this X.25
                PLE."
        ::= { x25 3 }

x25StatEntry OBJECT-TYPE
        SYNTAX  X25StatEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                 "Entries of the x25StatTable."
                 INDEX { x25StatIndex }
        ::= { x25StatTable 1 }

X25StatEntry ::= SEQUENCE {
        x25StatIndex
                IfIndexType,
        x25StatInCalls
                Counter,
        x25StatInCallRefusals
                Counter,
        x25StatInProviderInitiatedClears
                Counter,
        x25StatInRemotelyInitiatedResets
                Counter,
        x25StatInProviderInitiatedResets
                Counter,
        x25StatInRestarts
                Counter,
        x25StatInDataPackets
                Counter,
        x25StatInAccusedOfProtocolErrors
                Counter,
        x25StatInInterrupts
                Counter,
        x25StatOutCallAttempts
                Counter,
        x25StatOutCallFailures
                Counter,
        x25StatOutInterrupts
                Counter,
        x25StatOutDataPackets
                Counter,
        x25StatOutgoingCircuits
                Gauge,
        x25StatIncomingCircuits
                Gauge,
        x25StatTwowayCircuits
                Gauge,
        x25StatRestartTimeouts
                Counter,
        x25StatCallTimeouts
                Counter,
        x25StatResetTimeouts
                Counter,
        x25StatClearTimeouts
                Counter,
        x25StatDataRxmtTimeouts
                Counter,
        x25StatInterruptTimeouts
                Counter,
        x25StatRetryCountExceededs
                Counter,
        x25StatClearCountExceededs
                Counter
        }

x25StatIndex OBJECT-TYPE
        SYNTAX  IfIndexType
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The ifIndex value for the X.25 interface."
        ::= { x25StatEntry 1 }

x25StatInCalls OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The number of incoming calls received."
        ::= { x25StatEntry 2 }

x25StatInCallRefusals OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The number of incoming calls refused.  This
                includes calls refused by the PLE and by
                higher layers.  This also includes calls
                cleared because of restricted fast select."
        ::= { x25StatEntry 3 }

x25StatInProviderInitiatedClears        OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The number of clear requests with a cause
                code other than DTE initiated."
                REFERENCE "10733 providerInitiatedDisconnect"
        ::= { x25StatEntry 4 }

x25StatInRemotelyInitiatedResets        OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The number of reset requests received with
                cause code DTE initiated."
        REFERENCE "10733 remotelyInitiatedResets"
        ::= { x25StatEntry 5 }

x25StatInProviderInitiatedResets        OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The number of reset requests received with
                cause code other than DTE initiated."
        REFERENCE "10733 ProviderInitiatedResets"
        ::= { x25StatEntry 6 }

x25StatInRestarts OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The number of remotely initiated (including
                provider initiated) restarts experienced by
                the PLE excluding the restart associated
                with bringing up the PLE interface.  This
                only counts restarts received when the PLE
                already has an established connection with
                the remove PLE."
        REFERENCE "10733 5.9 remotelyInitiatedRestarts"
        ::= { x25StatEntry 7 }

x25StatInDataPackets    OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The number of data packets received."
                REFERENCE "10733 5.9 dataPacketsReceived."
        ::= { x25StatEntry 8 }

x25StatInAccusedOfProtocolErrors        OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The number of packets received containing a
                procedure error cause code.  These include
                clear, reset, restart, or diagnostic
                packets."
        REFERENCE "CD 10733 5.9 accusedOfProtocolError"
        ::= { x25StatEntry 9 }

x25StatInInterrupts OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The number of interrupt packets received by
                the PLE or over the PVC/VC."
        REFERENCE "10733 interruptPacketsReceived"
        ::= { x25StatEntry 10 }

x25StatOutCallAttempts OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The number of calls attempted."
        REFERENCE "10733 5.9 callAttempts"
        ::= { x25StatEntry 11 }

x25StatOutCallFailures OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The number of call attempts which failed.
                This includes calls that were cleared
                because of restrictive fast select."
        ::= { x25StatEntry 12 }

x25StatOutInterrupts    OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The number of interrupt packets send by the
                PLE or over the PVC/VC."
        REFERENCE "10733 InterruptPacketsSent"
        ::= { x25StatEntry 13 }

x25StatOutDataPackets   OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The number of data packets sent by this
                PLE."
        REFERENCE "10733 dataPacketSent"
        ::= { x25StatEntry 14 }

x25StatOutgoingCircuits OBJECT-TYPE
        SYNTAX  Gauge
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The number of active outgoing circuits.
                This includes call requests sent but not yet
                confirmed.  This does not count PVCs."
        ::= { x25StatEntry 15 }

x25StatIncomingCircuits OBJECT-TYPE
        SYNTAX  Gauge
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The number of active Incoming Circuits.
                This includes call indications received but
                not yet acknowledged.  This does not count
                PVCs."
        ::= { x25StatEntry 16 }

x25StatTwowayCircuits   OBJECT-TYPE
        SYNTAX  Gauge
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
        "The number of active two-way Circuits.
                This includes call requests sent but not yet
                confirmed.  This does not count PVCs."
        ::= { x25StatEntry 17 }

x25StatRestartTimeouts OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The number of times the T20 restart timer
                expired."
        REFERENCE "10733 5.9 restartTimeouts"
        ::= { x25StatEntry 18 }

x25StatCallTimeouts OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The number of times the T21 call timer
                expired."
        REFERENCE "10733 5.9 callTimeouts"
        ::= { x25StatEntry 19 }

x25StatResetTimeouts    OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The number of times the T22 reset timer
                expired."
        REFERENCE "10733 5.9 resetTimeouts"
        ::= { x25StatEntry 20 }

x25StatClearTimeouts    OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The number of times the T23 clear timer
                expired."
        REFERENCE "10733 5.9 clearTimeouts"
        ::= { x25StatEntry 21 }

x25StatDataRxmtTimeouts OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The number of times the T25 data timer
                expired."
        REFERENCE "10733 5.9 dataRetransmissionsTimerExpiries"
        ::= { x25StatEntry 22 }

x25StatInterruptTimeouts        OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The number of times the T26 interrupt timer
                expired."
        REFERENCE "10733 5.9 interruptTimerExpires"
        ::= { x25StatEntry 23 }

x25StatRetryCountExceededs OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The number of times a retry counter was
                exhausted."
        REFERENCE "10733 5.9 retryCountsExceeded"
        ::= { x25StatEntry 24 }

x25StatClearCountExceededs OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The number of times the R23 clear count was
                exceeded."
        REFERENCE "10733 5.9 clearCountsExceeded"
        ::= { x25StatEntry 25 }


--      MIB-II also contains:

-- ifInOctets: Number of data octets delivered to upper
-- layer entities.

-- ifInUcastPkts: Number of packets with a clear M-bit
-- delivered to higher layer entities.

-- ifDiscards: Number of packets dropped for lack of buffering

-- ifInErrors: Number of packets received containing errors
  -- REFERENCE ProtocolErrorsDetectedLocally

-- ifInUnknownProtos: Number of packets with unknown circuit
-- identifier.

-- ifOutOctets: Number of data octets delivered by
--      X.25 to upper layers.

-- ifOutUcastPkts: Number of packets with a clear M-bit
-- received from higher layer entities.


-- ###########################################################
--                    X.25 Channel Table
-- ###########################################################

x25ChannelTable OBJECT-TYPE
        SYNTAX  SEQUENCE OF X25ChannelEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                "These objects contain information about the
                channel number configuration in an X.25 PLE.
                These values are the configured values.
                changes in these values after the interfaces
                has started may not be reflected in the
                operating PLE."
        REFERENCE "See ISO 8208, Section 3.7"
        ::= { x25 4 }

x25ChannelEntry OBJECT-TYPE
        SYNTAX  X25ChannelEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                "Entries of x25ChannelTable."
        REFERENCE "This provides the information available
                in 10733 logicalChannelAssignments."
        INDEX { x25ChannelIndex }
        ::= { x25ChannelTable 1    }

X25ChannelEntry ::= SEQUENCE {
        x25ChannelIndex
                IfIndexType,
        x25ChannelLIC
                INTEGER,
        x25ChannelHIC
                INTEGER,
        x25ChannelLTC
                INTEGER,
        x25ChannelHTC
                INTEGER,
        x25ChannelLOC
                INTEGER,
        x25ChannelHOC
                INTEGER
        }

x25ChannelIndex OBJECT-TYPE
        SYNTAX  IfIndexType
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The ifIndex value for the X.25 Interface."
        ::= { x25ChannelEntry 1 }

x25ChannelLIC OBJECT-TYPE
        SYNTAX  INTEGER (0..4095)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Lowest Incoming channel."
        ::= { x25ChannelEntry 2 }

x25ChannelHIC OBJECT-TYPE
        SYNTAX  INTEGER (0..4095)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Highest Incoming channel.  A value of zero
                indicates no channels in this range."
        ::= { x25ChannelEntry 3 }

x25ChannelLTC OBJECT-TYPE
        SYNTAX  INTEGER (0..4095)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Lowest Two-way channel."
        ::= { x25ChannelEntry 4 }

x25ChannelHTC OBJECT-TYPE
        SYNTAX  INTEGER (0..4095)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Highest Two-way channel.  A value of zero
                indicates no channels in this range."
        ::= { x25ChannelEntry 5 }

x25ChannelLOC OBJECT-TYPE
        SYNTAX  INTEGER (0..4095)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Lowest outgoing channel."
        ::= { x25ChannelEntry 6 }

x25ChannelHOC OBJECT-TYPE
        SYNTAX  INTEGER (0..4095)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Highest outgoing channel.  A value of zero
                indicates no channels in this range."
        ::= { x25ChannelEntry 7 }




-- ###########################################################
--          X25 Per Circuits Information Table
-- ###########################################################

x25CircuitTable OBJECT-TYPE
        SYNTAX  SEQUENCE OF X25CircuitEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                "These objects contain general information
                about a specific circuit of an X.25 PLE."
        ::= { x25 5 }

x25CircuitEntry OBJECT-TYPE
        SYNTAX  X25CircuitEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                "Entries of x25CircuitTable."
        INDEX { x25CircuitIndex,
                x25CircuitChannel }
        ::= { x25CircuitTable 1 }

X25CircuitEntry ::= SEQUENCE {
        x25CircuitIndex
                IfIndexType,
        x25CircuitChannel
                INTEGER,
        x25CircuitStatus
                INTEGER,
        x25CircuitEstablishTime
                TimeTicks,
        x25CircuitDirection
                INTEGER,
        x25CircuitInOctets
                Counter,
        x25CircuitInPdus
                Counter,
        x25CircuitInRemotelyInitiatedResets
                Counter,
        x25CircuitInProviderInitiatedResets
                Counter,
        x25CircuitInInterrupts
                Counter,
        x25CircuitOutOctets
                Counter,
        x25CircuitOutPdus
                Counter,
        x25CircuitOutInterrupts
                Counter,
        x25CircuitDataRetransmissionTimeouts
                Counter,
        x25CircuitResetTimeouts
                Counter,
        x25CircuitInterruptTimeouts
                Counter,
        x25CircuitCallParamId
                OBJECT IDENTIFIER,
        x25CircuitCalledDteAddress
                X121Address,
        x25CircuitCallingDteAddress
                X121Address,
        x25CircuitOriginallyCalledAddress
                X121Address,
        x25CircuitDescr
                DisplayString
        }

x25CircuitIndex OBJECT-TYPE
        SYNTAX  IfIndexType
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The ifIndex value for the X.25 Interface."
        ::= { x25CircuitEntry 1 }

x25CircuitChannel OBJECT-TYPE
        SYNTAX  INTEGER (0..4095)
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The channel number for this circuit."
        ::= { x25CircuitEntry 2 }

x25CircuitStatus OBJECT-TYPE
        SYNTAX  INTEGER {               -- state table states
                        invalid (1),
                        closed (2),             -- (p1)
                        calling (3),            -- (p2,p3,p5)
                        open (4),               -- (p4)
                        clearing (5),           -- (p6,p7)
                        pvc (6),
                        pvcResetting (7),
                        startClear (8),         -- Close cmd
                        startPvcResetting (9),  -- Reset cmd
                        other (10)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "This object reports the current status of
                the circuit.

                An existing instance of this object can only
                be set to startClear, startPvcResetting, or
                invalid.  An instance with the value calling
                or open can only be set to startClear and
                that action will start clearing the circuit.
                An instance with the value PVC can only be
                set to startPvcResetting or invalid and that
                action resets the PVC or deletes the circuit
                respectively.  The values startClear or
                startPvcResetting will never be returned by
                an agent.  An attempt to set the status of
                an existing instance to a value other than
                one of these values will result in an error.

                A non-existing instance can be set to PVC to
                create a PVC if the implementation supports
                dynamic creation of PVCs.  Some
                implementations may only allow creation and
                deletion of PVCs if the interface is down.
                Since the instance identifier will supply
                the PLE index and the channel number,
                setting this object alone supplies
                sufficient information to create the
                instance.  All the DEFVAL clauses for the
                other objects of this table are appropriate
                for creating a PVC; PLEs creating entries
                for placed or accepted calls will use values
                appropriate for the call rather than the
                value of the DEFVAL clause.  Two managers
                trying to create the same PVC can determine
                from the return code which manager succeeded
                and which failed (the failing manager fails
                because it can not set a value of PVC for an
                existing object).
                An entry in the closed or invalid state may
                be deleted or reused at the agent's
                convence.  If the entry is kept in the
                closed state, the values of the parameters
                associated with the entry must be correct.
                Closed implies the values in the circuit
                table are correct.

                The value of invalid indicates the other
                values in the table are invalid.  Many
                agents may never return a value of invalid
                because they dynamically allocate and free
                unused table entries.  An agent for a
                statically configured systems can return
                invalid to indicate the entry has not yet
                been used so the counters contain no
                information."
        REFERENCE "See ISO 8208,
                        table 33 for (p<n>) state table"
        ::= { x25CircuitEntry 3 }

x25CircuitEstablishTime OBJECT-TYPE
        SYNTAX  TimeTicks
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The value of sysUpTime when the channel was
                associated with this circuit.  For outgoing
                SVCs, this is the time the first call packet
                was sent.  For incoming SVCs, this is the
                time the call indication was received.  For
                PVCs this is the time the PVC was able to
                pass data to a higher layer entity without
                loss of data."
        ::= { x25CircuitEntry 4 }

x25CircuitDirection OBJECT-TYPE
        SYNTAX  INTEGER {
                        incoming (1),
                        outgoing (2),
                        pvc (3)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The direction of the call that established
                this circuit."
        REFERENCE "10733 direction"
        DEFVAL { pvc }
        ::= { x25CircuitEntry 5 }

                -- X25 Circuit data flow statistics

x25CircuitInOctets OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The number of octets of user data delivered
                to upper layer."
        REFERENCE "5.11 octetsReceivedCounter"
        ::= { x25CircuitEntry 6 }

x25CircuitInPdus OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The number of PDUs received for this
                circuit."
        REFERENCE "10733 5.11 dataPacketsReceived"
        ::= { x25CircuitEntry 7 }

x25CircuitInRemotelyInitiatedResets OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The number of Resets received for this
                circuit with cause code of DTE initiated."
        REFERENCE "10733 remotelyInitiatedResets"
        ::= { x25CircuitEntry 8 }

x25CircuitInProviderInitiatedResets OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The number of Resets received for this
                circuit with cause code other than DTE
                initiated."
        REFERENCE "10733 ProviderInitiatedResets"
        ::= { x25CircuitEntry 9 }

x25CircuitInInterrupts OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The number of interrupt packets received
                for this circuit."
        REFERENCE "10733 interruptPacketsReceived"
        ::= { x25CircuitEntry 10 }

x25CircuitOutOctets OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The number of octets of user data sent for
                this circuit."
        REFERENCE "10733 5.11 octetsSentCounter"
        ::= { x25CircuitEntry 11 }

x25CircuitOutPdus OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The number of PDUs sent for this circuit."
        REFERENCE "10733 5.11 dataPacketsSent"
        ::= { x25CircuitEntry 12 }

x25CircuitOutInterrupts OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The number of interrupt packets sent on
                this circuit."
        REFERENCE "10733 interruptPacketsSent"
        ::= { x25CircuitEntry 13 }


                -- X25 circuit timer statistics

x25CircuitDataRetransmissionTimeouts OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The number of times the T25 data
                retransmission timer expired for this
                circuit."
        REFERENCE "10733 5.11 dataRetransmissionTimerExpiries"
        ::= { x25CircuitEntry 14 }

x25CircuitResetTimeouts OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The number of times the T22 reset timer
                expired for this circuit."
        REFERENCE "10733 5.11 resetTimeouts"
        ::= { x25CircuitEntry 15 }

x25CircuitInterruptTimeouts OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The number of times the T26 Interrupt timer
                expired for this circuit."
        REFERENCE "10733 interruptTimerExpiries"
        ::= { x25CircuitEntry 16 }

x25CircuitCallParamId OBJECT-TYPE
        SYNTAX  OBJECT IDENTIFIER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "This identifies the instance of the
                x25CallParmIndex for the entry in the
                x25CallParmTable which contains the call
                parameters in use with this circuit.  The
                entry referenced must contain the values
                that are currently in use by the circuit
                rather than proposed values.  A value of
                NULL indicates the circuit is a PVC or is
                using all the default parameters."
        DEFVAL { {0 0} }
        ::= { x25CircuitEntry 17 }

x25CircuitCalledDteAddress OBJECT-TYPE
        SYNTAX  X121Address
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "For incoming calls, this is the called
                address from the call indication packet.
                For outgoing calls, this is the called
                address from the call confirmation packet.
                This will be zero length for PVCs."
        REFERENCE "10733 calledDTEAddress"
        DEFVAL { ''h }
        ::= { x25CircuitEntry 18 }

x25CircuitCallingDteAddress OBJECT-TYPE
        SYNTAX  X121Address
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "For incoming calls, this is the calling
                address from the call indication packet.
                For outgoing calls, this is the calling
                address from the call confirmation packet.
                This will be zero length for PVCs."
        REFERENCE "10733 callingDTEAddress"
        DEFVAL { ''h }
        ::= { x25CircuitEntry 19 }

x25CircuitOriginallyCalledAddress OBJECT-TYPE
        SYNTAX  X121Address
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "For incoming calls, this is the address in
                the call Redirection or Call Deflection
                Notification facility if the call was
                deflected or redirected, otherwise it will
                be called address from the call indication
                packet.  For outgoing calls, this is the
                address from the call request packet.  This
                will be zero length for PVCs."
        REFERENCE "10733 originallyCalledAddress"
        DEFVAL { ''h }
        ::= { x25CircuitEntry 20 }

x25CircuitDescr OBJECT-TYPE
        SYNTAX  DisplayString (SIZE (0..255))
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "A descriptive string associated with this
                circuit.  This provides a place for the
                agent to supply any descriptive information
                it knows about the use or owner of the
                circuit.  The agent may return the process
                identifier and user name for the process
                using the circuit.  Alternative the agent
                may return the name of the configuration
                entry that caused a bridge to establish the
                circuit.  A zero length value indicates the
                agent doesn't have any additional
                information."
        DEFVAL { ''h }
        ::= { x25CircuitEntry 21 }



-- ###########################################################
--              The Cleared Circuit Table
-- ###########################################################

x25ClearedCircuitEntriesRequested OBJECT-TYPE
        SYNTAX  PositiveInteger
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The requested number of entries for the
                agent to keep in the x25ClearedCircuit
                table."
        ::= { x25 6 }

x25ClearedCircuitEntriesGranted OBJECT-TYPE
        SYNTAX  PositiveInteger
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The actual number of entries the agent will
                keep in the x25ClearedCircuit Table."
        ::= { x25 7 }

x25ClearedCircuitTable  OBJECT-TYPE
        SYNTAX SEQUENCE OF      X25ClearedCircuitEntry
        ACCESS not-accessible
        STATUS  mandatory
        DESCRIPTION
                "A table of entries about closed circuits.
                Entries must be made in this table whenever
                circuits are closed and the close request or
                close indication packet contains a clearing
                cause other than DTE Originated or a
                Diagnostic code field other than Higher
                Layer Initiated disconnection-normal.  An
                agent may optionally make entries for normal
                closes (to record closing facilities or
                other information).

                Agents will delete the oldest entry in the
                table when adding a new entry would exceed
                agent resources.  Agents are required to
                keep the last entry put in the table and may
                keep more entries.  The object
                x25OperClearEntriesGranted returns the
                maximum number of entries kept in the
                table."
        REFERENCE "See ISO 8208 Section 12.2.3.1.1
                        and 12.2.3.1.2"
        ::= { x25 8 }

x25ClearedCircuitEntry  OBJECT-TYPE
        SYNTAX  X25ClearedCircuitEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                "Information about a cleared circuit."
        INDEX { x25ClearedCircuitIndex }
        ::= { x25ClearedCircuitTable 1 }

X25ClearedCircuitEntry ::= SEQUENCE {
        x25ClearedCircuitIndex
                PositiveInteger,
        x25ClearedCircuitPleIndex
                IfIndexType,
        x25ClearedCircuitTimeEstablished
                TimeTicks,
        x25ClearedCircuitTimeCleared
                TimeTicks,
        x25ClearedCircuitChannel
                INTEGER,
        x25ClearedCircuitClearingCause
                INTEGER,
        x25ClearedCircuitDiagnosticCode
                INTEGER,
        x25ClearedCircuitInPdus
                Counter,
        x25ClearedCircuitOutPdus
                Counter,
        x25ClearedCircuitCalledAddress
                X121Address,
        x25ClearedCircuitCallingAddress
                X121Address,
        x25ClearedCircuitClearFacilities
                OCTET STRING
        }

x25ClearedCircuitIndex OBJECT-TYPE
        SYNTAX  PositiveInteger
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "An index that uniquely distinguishes one
                entry in the clearedCircuitTable from
                another.  This index will start at
                2147483647 and will decrease by one for each
                new entry added to the table.  Upon reaching
                one, the index will reset to 2147483647.
                Because the index starts at 2147483647 and
                decreases, a manager may do a getnext on
                entry zero and obtain the most recent entry.
                When the index has the value of 1, the next
                entry will delete all entries in the table
                and that entry will be numbered 2147483647."
        ::= { x25ClearedCircuitEntry 1 }

x25ClearedCircuitPleIndex OBJECT-TYPE
        SYNTAX  IfIndexType
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The value of ifIndex for the PLE which
                cleared the circuit that created the entry."
        ::= { x25ClearedCircuitEntry 2 }

x25ClearedCircuitTimeEstablished OBJECT-TYPE
        SYNTAX  TimeTicks
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The value of sysUpTime when the circuit was
                established.  This will be the same value
                that was in the x25CircuitEstablishTime for
                the circuit."
        ::= { x25ClearedCircuitEntry 3 }

x25ClearedCircuitTimeCleared OBJECT-TYPE
        SYNTAX  TimeTicks
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The value of sysUpTime when the circuit was
                cleared.  For locally initiated clears, this
                will be the time when the clear confirmation
                was received.  For remotely initiated
                clears, this will be the time when the clear
                indication was received."
        ::= { x25ClearedCircuitEntry 4 }

x25ClearedCircuitChannel OBJECT-TYPE
        SYNTAX  INTEGER (0..4095)
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The channel number for the circuit that was
                cleared."
        ::= { x25ClearedCircuitEntry 5 }

x25ClearedCircuitClearingCause OBJECT-TYPE
        SYNTAX  INTEGER (0..255)
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The Clearing Cause from the clear request
                or clear indication packet that cleared the
                circuit."
        REFERENCE "See ISO 8208 Section 12.2.3.1.1"
        ::= { x25ClearedCircuitEntry 6 }

x25ClearedCircuitDiagnosticCode OBJECT-TYPE
        SYNTAX  INTEGER (0..255)
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The Diagnostic Code from the clear request
                or clear indication packet that cleared the
                circuit."
        REFERENCE "See ISO 8208 Section 12.2.3.1.2"
        ::= { x25ClearedCircuitEntry 7 }

x25ClearedCircuitInPdus OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The number of PDUs received on the
                circuit."
        ::= { x25ClearedCircuitEntry 8 }

x25ClearedCircuitOutPdus OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The number of PDUs transmitted on the
                circuit."
        ::= { x25ClearedCircuitEntry 9 }

x25ClearedCircuitCalledAddress OBJECT-TYPE
        SYNTAX  X121Address
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The called address from the cleared
                circuit."
        ::= { x25ClearedCircuitEntry 10 }

x25ClearedCircuitCallingAddress OBJECT-TYPE
        SYNTAX  X121Address
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The calling address from the cleared
                circuit."
        ::= { x25ClearedCircuitEntry 11 }

x25ClearedCircuitClearFacilities OBJECT-TYPE
        SYNTAX  OCTET STRING (SIZE (0..109))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The facilities field from the clear request
                or clear indication packet that cleared the
                circuit.  A size of zero indicates no
                facilities were present."
        ::= { x25ClearedCircuitEntry 12 }




-- ###########################################################
--                The Call Parameter Table
-- ###########################################################

x25CallParmTable OBJECT-TYPE
        SYNTAX  SEQUENCE OF X25CallParmEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                "These objects contain the parameters that
                can be varied between X.25 calls.  The
                entries in this table are independent of the
                PLE.  There exists only one of these tables
                for the entire system.  The indexes for the
                entries are independent of any PLE or any
                circuit.  Other tables reference entries in
                this table.  Entries in this table can be
                used for default PLE parameters, for
                parameters to use to place/answer a call,
                for the parameters currently in use for a
                circuit, or parameters that were used by a
                circuit.

                The number of references to a given set of
                parameters can be found in the
                x25CallParmRefCount object sharing the same
                instance identifier with the parameters.
                The value of this reference count also
                affects the access of the objects in this
                table.  An object in this table with the
                same instance identifier as the instance
                identifier of an x25CallParmRefCount must be
                consider associated with that reference
                count.  An object with an associated
                reference count of zero can be written (if
                its ACCESS clause allows it).  An object
                with an associated reference count greater
                than zero can not be written (regardless of
                the ACCESS clause).  This ensures that a set
                of call parameters being referenced from
                another table can not be modified or changed
                in a ways inappropriate for continued use by
                that table."
        ::= { x25 9 }

x25CallParmEntry OBJECT-TYPE
        SYNTAX  X25CallParmEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
                "Entries of x25CallParmTable."
        INDEX { x25CallParmIndex }
        ::= { x25CallParmTable 1 }

X25CallParmEntry ::= SEQUENCE {
        x25CallParmIndex
                PositiveInteger,
        x25CallParmStatus
                EntryStatus,
        x25CallParmRefCount
                PositiveInteger,
        x25CallParmInPacketSize
                INTEGER,
        x25CallParmOutPacketSize
                INTEGER,
        x25CallParmInWindowSize
                INTEGER,
        x25CallParmOutWindowSize
                INTEGER,
        x25CallParmAcceptReverseCharging
                INTEGER,
        x25CallParmProposeReverseCharging
                INTEGER,
        x25CallParmFastSelect
                INTEGER,
        x25CallParmInThruPutClasSize
                INTEGER,
        x25CallParmOutThruPutClasSize
                INTEGER,
        x25CallParmCug
                DisplayString,
        x25CallParmCugoa
                DisplayString,
        x25CallParmBcug
                DisplayString,
        x25CallParmNui
                OCTET STRING,
        x25CallParmChargingInfo
                INTEGER,
        x25CallParmRpoa
                DisplayString,
        x25CallParmTrnstDly
                INTEGER,
        x25CallParmCallingExt
                DisplayString,
        x25CallParmCalledExt
                DisplayString,
        x25CallParmInMinThuPutCls
                INTEGER,
        x25CallParmOutMinThuPutCls
                INTEGER,
        x25CallParmEndTrnsDly
                OCTET STRING,
        x25CallParmPriority
                OCTET STRING,
        x25CallParmProtection
                DisplayString,
        x25CallParmExptData
                INTEGER,
        x25CallParmUserData
                OCTET STRING,
        x25CallParmCallingNetworkFacilities
                OCTET STRING,
        x25CallParmCalledNetworkFacilities
                OCTET STRING
        }

x25CallParmIndex OBJECT-TYPE
        SYNTAX  PositiveInteger
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "A value that distinguishes this entry from
                another entry.  Entries in this table are
                referenced from other objects which identify
                call parameters.

                It is impossible to know which other objects
                in the MIB reference entries in the table by
                looking at this table.  Because of this,
                changes to parameters must be accomplished
                by creating a new entry in this table and
                then changing the referencing table to
                identify the new entry.

                Note that an agent will only use the values
                in this table when another table is changed
                to reference those values.  The number of
                other tables that reference an index object
                in this table can be found in
                x25CallParmRefCount.  The value of the
                reference count will affect the writability
                of the objects as explained above.

                Entries in this table which have a reference
                count of zero maybe deleted at the convence
                of the agent.  Care should be taken by the
                agent to give the NMS sufficient time to
                create a reference to newly created entries.

                Should a Management Station not find a free
                index with which to create a new entry, it
                may feel free to delete entries with a
                reference count of zero.  However in doing
                so the Management Station much realize it
                may impact other Management Stations."
        ::= { x25CallParmEntry 1 }

x25CallParmStatus OBJECT-TYPE
        SYNTAX  EntryStatus
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The status of this call parameter entry.
                See RFC 1271 for details of usage."
        ::= { x25CallParmEntry 2 }

x25CallParmRefCount OBJECT-TYPE
        SYNTAX  PositiveInteger
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The number of references know by a
                management station to exist to this set of
                call parameters.  This is the number of
                other objects that have returned a value of,
                and will return a value of, the index for
                this set of call parameters.  Examples of
                such objects are the x25AdmnDefCallParamId,
                x25OperDataLinkId, or x25AdmnDefCallParamId
                objects defined above."
        ::= { x25CallParmEntry 3 }

x25CallParmInPacketSize OBJECT-TYPE
        SYNTAX  INTEGER (0..4096)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The maximum receive packet size in octets
                for a circuit.  A size of zero for a circuit
                means use the PLE default size.  A size of
                zero for the PLE means use a default size of
                128."
        REFERENCE "10733 proposedPacketSize;
                See ISO 8208 Section 15.2.2.1.1"
        DEFVAL { 128 }
        ::= { x25CallParmEntry 4 }

x25CallParmOutPacketSize OBJECT-TYPE
        SYNTAX  INTEGER (0..4096)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The maximum transmit packet size in octets
                for a circuit.  A size of zero for a circuit
                means use the PLE default size.  A size of
                zero for the PLE default means use a default
                size of 128."
        REFERENCE "10733 proposedPacketSize;
                See ISO 8208 Section 15.2.2.1.1"
        DEFVAL { 128 }
        ::= { x25CallParmEntry 5 }

x25CallParmInWindowSize OBJECT-TYPE
        SYNTAX  INTEGER (0..127)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The receive window size for a circuit.  A
                size of zero for a circuit means use the PLE
                default size.  A size of zero for the PLE
                default means use 2."
        REFERENCE "10733 proposedWindowSize;
                See ISO 8208 Section 15.2.2.1.2"
        DEFVAL { 2 }
        ::= { x25CallParmEntry 6 }

x25CallParmOutWindowSize OBJECT-TYPE
        SYNTAX  INTEGER (0..127)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The transmit window size for a circuit.  A
                size of zero for a circuit means use the PLE
                default size.  A size of zero for the PLE
                default means use 2."
        REFERENCE "10733 proposedWindowSize;
                See ISO 8208 Section 15.2.2.1.2"
        DEFVAL { 2 }
        ::= { x25CallParmEntry 7 }

x25CallParmAcceptReverseCharging OBJECT-TYPE
        SYNTAX  INTEGER {
                        default (1),
                        accept (2),
                        refuse (3),
                        neverAccept (4)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "An enumeration defining if the PLE will
                accept or refuse charges.  A value of
                default for a circuit means use the PLE
                default value.  A value of neverAccept is
                only used for the PLE default and indicates
                the PLE will never accept reverse charging.
                A value of default for a PLE default means
                refuse."
        REFERENCE "10733 acceptReverseCharging"
        DEFVAL { refuse }
        ::= { x25CallParmEntry 8 }

x25CallParmProposeReverseCharging OBJECT-TYPE
        SYNTAX  INTEGER {
                        default (1),
                        reverse (2),
                        local (3)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "An enumeration defining if the PLE should
                propose reverse or local charging.  The
                value of default for a circuit means use the
                PLE default.  The value of default for the
                PLE default means use local."
        REFERENCE "10733 proposedPacketSize;
                See ISO 8208 Section 15.2.2.6"
        DEFVAL { local }
        ::= { x25CallParmEntry 9 }

x25CallParmFastSelect OBJECT-TYPE
        SYNTAX  INTEGER {
                        default (1),
                        notSpecified (2),
                        fastSelect (3),
                        restrictedFastResponse (4),
                        noFastSelect (5),
                        noRestrictedFastResponse (6)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Expresses preference for use of fast select
                facility.  The value of default for a
                circuit is the PLE default.  A value of
                default for the PLE means noFastSelect.  A
                value of noFastSelect or
                noRestrictedFastResponse indicates a circuit
                may not use fast select or restricted fast
                response."
        REFERENCE "10733 fastSelect;
        Sec ISO 8208 Section 15.2.2.6"
        DEFVAL { noFastSelect }
        ::= { x25CallParmEntry 10 }

x25CallParmInThruPutClasSize    OBJECT-TYPE
        SYNTAX  INTEGER {
                        tcReserved1 (1),
                        tcReserved2 (2),
                        tc75 (3),
                        tc150 (4),
                        tc300 (5),
                        tc600 (6),
                        tc1200  (7),
                        tc2400  (8),
                        tc4800  (9),
                        tc9600  (10),
                        tc19200 (11),
                        tc48000 (12),
                        tc64000 (13),
                        tcReserved14 (14),
                        tcReserved15 (15),
                        tcReserved0 (16),
                        tcNone  (17),
                        tcDefault (18)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The incoming throughput class to negotiate.
                A value of tcDefault for a circuit means use
                the PLE default.  A value of tcDefault for
                the PLE default means tcNone.  A value of
                tcNone means do not negotiate throughtput
                class."
        REFERENCE "See ISO 8208 Section 15.2.2.2, table 18"
        DEFVAL { tcNone }
        ::= { x25CallParmEntry 11 }

x25CallParmOutThruPutClasSize   OBJECT-TYPE
        SYNTAX  INTEGER {
                        tcReserved1 (1),
                        tcReserved2 (2),
                        tc75 (3),
                        tc150 (4),
                        tc300 (5),
                tc600 (6),
                        tc1200  (7),
                        tc2400  (8),
                        tc4800  (9),
                        tc9600  (10),
                        tc19200 (11),
                        tc48000 (12),
                        tc64000 (13),
                        tcReserved14 (14),
                        tcReserved15 (15),
                        tcReserved0 (16),
                        tcNone  (17),
                        tcDefault (18)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The outgoing throughput class to negotiate.
                A value of tcDefault for a circuit means use
                the PLE default.  A value of tcDefault for
                the PLE default means use tcNone.  A value
                of tcNone means do not negotiate throughtput
                class."
        REFERENCE "See ISO 8208 Section 15.2.2.2, table 18"
        DEFVAL { tcNone }
        ::= { x25CallParmEntry 12 }

x25CallParmCug  OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..4))
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The Closed User Group to specify.  This
                consists of two or four octets containing
                the characters 0 through 9.  A zero length
                string indicates no facility requested.  A
                string length of three containing the
                characters DEF for a circuit means use the
                PLE default, (the PLE default parameter may
                not reference an entry of DEF.)"
        REFERENCE "See ISO 8208 Section 15.2.2.3"
        DEFVAL { ''h }
        ::= { x25CallParmEntry 13 }

x25CallParmCugoa        OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..4))
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The Closed User Group with Outgoing Access
                to specify.  This consists of two or four
                octets containing the characters 0 through
                9.  A string length of three containing the
                characters DEF for a circuit means use the
                PLE default (the PLE default parameters may
                not reference an entry of DEF).  A zero
                length string indicates no facility
                requested."
        REFERENCE "See ISO 8208 Section 15.2.2.4"
        DEFVAL { ''h }
        ::= { x25CallParmEntry 14 }

x25CallParmBcug OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..3))
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The Bilateral Closed User Group to specify.
                This consists of two octets containing the
                characters 0 through 9.  A string length of
                three containing the characters DEF for a
                circuit means use the PLE default (the PLE
                default parameter may not reference an entry
                of DEF).  A zero length string indicates no
                facility requested."
        REFERENCE "See ISO 8208 Section 15.2.2.5"
        DEFVAL { ''h }
        ::= { x25CallParmEntry 15 }

x25CallParmNui  OBJECT-TYPE
        SYNTAX  OCTET STRING (SIZE(0..108))
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The Network User Identifier facility.  This
                is binary value to be included immediately
                after the length field.  The PLE will supply
                the length octet.  A zero length string
                indicates no facility requested.  This value
                is ignored for the PLE default parameters
                entry."
        REFERENCE "See ISO 8208 Section 15.2.2.7"
        DEFVAL { ''h }
        ::= { x25CallParmEntry 16 }

x25CallParmChargingInfo OBJECT-TYPE
        SYNTAX INTEGER {
                        default (1),
                        noFacility (2),
                        noChargingInfo (3),
                        chargingInfo (4)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The charging Information facility.  A value
                of default for a circuit means use the PLE
                default.  The value of default for the
                default PLE parameters means use noFacility.
                The value of noFacility means do not include
                a facility."
        REFERENCE "See ISO 8208 Section 15.2.2.8"
        DEFVAL { noFacility }
        ::= { x25CallParmEntry 17 }

x25CallParmRpoa OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..108))
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The RPOA facility.  The octet string
                contains n * 4 sequences of the characters
                0-9 to specify a facility with n entries.
                The octet string containing the 3 characters
                DEF for a circuit specifies use of the PLE
                default (the entry for the PLE default may
                not contain DEF).  A zero length string
                indicates no facility requested."
        REFERENCE "See ISO 8208, section 15.2.2.9"
        DEFVAL { ''h }
        ::= { x25CallParmEntry 18 }

x25CallParmTrnstDly     OBJECT-TYPE
        SYNTAX  INTEGER (0..65537)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The Transit Delay Selection and Indication
                value.  A value of 65536 indicates no
                facility requested.  A value of 65537 for a
                circuit means use the PLE default (the PLE
                default parameters entry may not use the
                value 65537).  The value 65535 may only be
                used to indicate the value in use by a
                circuit."
        REFERENCE "See ISO 8208, Section 15.2.2.13"
        DEFVAL { 65536 }
        ::= { x25CallParmEntry 19 }


        -- The following parameters are for CCITT facilities.

x25CallParmCallingExt OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..40))
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The Calling Extension facility.  This
                contains one of the following:

                A sequence of hex digits with the value to
                be put in the facility. These digits will be
                converted to binary by the agent and put in
                the facility.  These octets do not include
                the length octet.

                A value containing the three character DEF
                for a circuit means use the PLE default,
                (the entry for the PLE default parameters
                may not use the value DEF).

                A zero length string indicates no facility
                requested."
        REFERENCE "See ISO 8208 Section 15.3.2.1"
        DEFVAL { ''h }
        ::= { x25CallParmEntry 20 }

x25CallParmCalledExt OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..40))
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The Called Extension facility.  This
                contains one of the following:

                A sequence of hex digits with the value to
                be put in the facility.  These digits will be
                converted to binary by the agent and put in
                the facility.  These octets do not include
                the length octet.

                A value containing the three character DEF
                for a circuit means use the PLE default,
                (the entry for the PLE default parameters
                may not use the value DEF).

                A zero length string indicates no facility
                requested."
        REFERENCE "See ISO 8208 Section 15.3.2.2"
        DEFVAL { ''h }
        ::= { x25CallParmEntry 21 }

x25CallParmInMinThuPutCls       OBJECT-TYPE
        SYNTAX  INTEGER (0..17)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The minimum input throughput Class.  A
                value of 16 for a circuit means use the PLE
                default (the PLE parameters entry may not
                use this value).  A value of 17 indicates no
                facility requested."
        REFERENCE "See ISO 8208 Section 15.3.2.3"
        DEFVAL { 17 }
        ::= { x25CallParmEntry 22 }

x25CallParmOutMinThuPutCls OBJECT-TYPE
        SYNTAX  INTEGER (0..17)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The minimum output throughput Class.  A
                value of 16 for a circuit means use the PLE
                default (the PLE parameters entry may not
                use this value).  A value of 17 indicates no
                facility requested."
        REFERENCE "See ISO 8208 Section 15.3.2.3"
        DEFVAL { 17 }
        ::= { x25CallParmEntry 23 }

x25CallParmEndTrnsDly OBJECT-TYPE
        SYNTAX  OCTET STRING (SIZE(0..6))
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The End-to-End Transit Delay to negotiate.
                An octet string of length 2, 4, or 6
                contains the facility encoded as specified
                in ISO/IEC 8208 section 15.3.2.4.  An octet
                string of length 3 containing the three
                character DEF for a circuit means use the
                PLE default (the entry for the PLE default
                can not contain the characters DEF).  A zero
                length string indicates no facility
                requested."
        REFERENCE "See ISO 8208 Section 15.3.2.4"
        DEFVAL { ''h }
        ::= { x25CallParmEntry 24 }

x25CallParmPriority OBJECT-TYPE
        SYNTAX  OCTET STRING (SIZE(0..6))
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The priority facility to negotiate.  The
                octet string encoded as specified in ISO/IEC
                8208 section 15.3.2.5.  A zero length string
                indicates no facility requested.  The entry
                for the PLE default parameters must be zero
                length."
        REFERENCE "See ISO 8208 Section 15.3.2.5"
        DEFVAL { ''h }
        ::= { x25CallParmEntry 25 }

x25CallParmProtection OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..108))
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "A string contains the following:
                A hex string containing the value for the
                protection facility.  This will be converted
                from hex to the octets actually in the
                packet by the agent.  The agent will supply
                the length field and the length octet is not
                contained in this string.

                An string containing the 3 characters DEF
                for a circuit means use the PLE default (the
                entry for the PLE default parameters may not
                use the value DEF).

                A zero length string mean no facility
                requested."
        REFERENCE "See ISO 8208 Section 15.3.2.5"
        DEFVAL { ''h }
        ::= { x25CallParmEntry 26 }

x25CallParmExptData OBJECT-TYPE
        SYNTAX  INTEGER {
                        default (1),
                        noExpeditedData (2),
                        expeditedData (3)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The Expedited Data facility to negotiate.
                A value of default for a circuit means use
                the PLE default value.  The entry for the
                PLE default parameters may not have the
                value default."
        REFERENCE "See ISO 8208 Section 15.3.2.7"
        DEFVAL { noExpeditedData }
        ::= { x25CallParmEntry 27 }

x25CallParmUserData     OBJECT-TYPE
        SYNTAX  OCTET STRING (SIZE (0..128))
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The call user data as placed in the packet.
                A zero length string indicates no call user
                data.  If both the circuit call parameters
                and the PLE default have call user data
                defined, the data from the circuit call
                parameters will be used.  If only the PLE
                has data defined, the PLE entry will be
                used.  If neither the circuit call
                parameters or the PLE default entry has a
                value, no call user data will be sent."
        REFERENCE "See ISO 8208 Section 12.2.1.1.6, 12.2.1.2"
        DEFVAL { ''h }
        ::= { x25CallParmEntry 28 }

x25CallParmCallingNetworkFacilities     OBJECT-TYPE
        SYNTAX  OCTET STRING (SIZE (0..108))
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The calling network facilities.  The
                facilities are encoded here exactly as
                encoded in the call packet.  These
                facilities do not include the marker
                facility code.

                A zero length string in the entry for the
                parameter to use when establishing a circuit
                means use the PLE default.  A zero length
                string in the entry for PLE default
                parameters indicates no default facilities."
        REFERENCE "See ISO 8206 Section 15.1, category b"
        DEFVAL { ''h }
        ::= { x25CallParmEntry 29 }

x25CallParmCalledNetworkFacilities      OBJECT-TYPE
        SYNTAX  OCTET STRING (SIZE (0..108))
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The called network facilities.  The
                facilities are encoded here exactly as
                encoded in the call packet.  These
                facilities do not include the marker
                facility code.

                A zero length string in the entry for the
                parameter to use when establishing a circuit
                means use the PLE default.  A zero length
                string in the entry for PLE default
                parameters indicates no default facilities."
        REFERENCE "See ISO 8206 Section 15.1, category c"
        DEFVAL { ''h }
        ::= { x25CallParmEntry 30 }

-- ###########################################################
--              X.25 Traps
-- ###########################################################

x25Restart      TRAP-TYPE
        ENTERPRISE  x25
        VARIABLES { x25OperIndex }
        DESCRIPTION
                "This trap means the X.25 PLE sent or
                received a restart packet.  The restart that
                brings up the link should not send a
                x25Restart trap so the interface should send
                a linkUp trap.  Sending this trap means the
                agent does not send a linkDown and linkUp
                trap."
        ::= 1

x25Reset        TRAP-TYPE
        ENTERPRISE  x25
        VARIABLES { x25CircuitIndex,
                x25CircuitChannel }
        DESCRIPTION
                "If the PLE sends or receives a reset, the
                agent should send an x25Reset trap."
        ::= 2


-- ###########################################################
--              X.25 Protocol Version Identifiers
-- ###########################################################

x25ProtocolVersion OBJECT IDENTIFIER
        ::= { x25 10 }

        -- X.25 CCITT 1976 version.
x25protocolCcittV1976 OBJECT IDENTIFIER
        ::= { x25ProtocolVersion 1 }

        -- X.25 CCITT 1980 version.
x25protocolCcittV1980 OBJECT IDENTIFIER
        ::= { x25ProtocolVersion 2 }

        -- X.25 CCITT 1984 version.
x25protocolCcittV1984 OBJECT IDENTIFIER
        ::= { x25ProtocolVersion 3 }

        -- X.25 CCITT 1988 version.
x25protocolCcittV1988 OBJECT IDENTIFIER
        ::= { x25ProtocolVersion 4 }

        -- X.25 1987 version of ISO 8208.
x25protocolIso8208V1987 OBJECT IDENTIFIER
        ::= { x25ProtocolVersion 5 }

        -- X.25 1989 version of ISO 8208.
x25protocolIso8208V1989 OBJECT IDENTIFIER
        ::= { x25ProtocolVersion 6 }

-- ###########################################################

END