Blob Blame History Raw
# bmc-snmp-proxy
#
# Config file to control SNMP redirection between
# the OS and Service Processor/Baseboard Management Controller (BMC)
#
# bmc-snnmp-proxy helps redirect certain SNMP requests (to this host)
# destined to the Service Processor. We will need the Service Processor's
# SNMP community string and the OID of the Service Processor's SNMP agent.
#
# For redirecting Traps from the Service Processor to the trap sink
# configured in the host (this system), we will have to set
# TRAP_FORWARD below.
#
# See here for details
#    https://fedoraproject.org/wiki/Features/AgentFreeManagement

### Configure SNMP proxy to BMC/Service Processor ###

### Service Processor/BMC SNMP Community String. 
# Name: BMC_COMMUNITY
# Description: Set community string of the Service Processor (BMC)'s
# 		SNMP agent.
# Default: public
#
BMC_COMMUNITY="public"

### OEM Specific OID of Service Processor
# Name: BMC_OID
# Description: SNMP OID that we would like to redirect to the Service
# 		Processor (BMC). This can be unique to each OEM.
# Default: ".1.3.6.1.4.1.674.10892.2"
BMC_OID=".1.3.6.1.4.1.674.10892.2"  # Dell iDRAC

### Forward Traps from the Service Processor to trap sink
# Name: TRAP_FORWARD
# Description: Enabling this will allow traps from the Service Processor
# 		to be directed to this system and configure snmptrapd
# Note: This option will have no effect if trap sink on the system is
# 	not configured
# Default: "no"
TRAP_FORWARD="yes"

### Reload snmpd and snmptrapd
# Name: RELOAD_SERVICES
# Description: Reload snmpd and snmptrapd after making changes to their config
# 		files.
# Default: "yes"
RELOAD_SERVICES="yes"