Blame configs/SuperMicro/X7SBi.conf

Packit 53d5b6
# Example configuration for the SuperMicro X7SBi. Contributed by Joe Ogulin.
Packit 53d5b6
Packit 53d5b6
# Monitoring hardware on this board: Winbond W83793G on ICH9 SMBus (driver
Packit 53d5b6
# w83793) and integrated sensors in the CPU (driver coretemp). A few voltages
Packit 53d5b6
# also available from the Winbond W83627HF Super-I/O chip.
Packit 53d5b6
Packit 53d5b6
Packit 53d5b6
# settings for the supermicro X7SBi
Packit 53d5b6
#
Packit 53d5b6
chip "w83793-*"
Packit 53d5b6
Packit 53d5b6
# 0x10, CPU Core
Packit 53d5b6
    label in0 "CPU Core"
Packit 53d5b6
# 0x11, unconnected according to support, 1.5V in BIOS ?
Packit 53d5b6
    label in1 "+1.5V"
Packit 53d5b6
    set in1_min 1.5*0.95
Packit 53d5b6
    set in1_max 1.5*1.05
Packit 53d5b6
# 0x12, unconnected according to support, VTT=1.2V in BIOS ?
Packit 53d5b6
    label in2 "VTT"
Packit 53d5b6
    set in2_min 1.2*0.95
Packit 53d5b6
    set in2_max 1.2*1.05
Packit 53d5b6
# 0x14, -12V
Packit 53d5b6
    label in3 "-12V"
Packit 53d5b6
#    From Supermicro support information...
Packit 53d5b6
#    compute in3 (((@/8)*18500)/256)-16, (((@+16)*256)/18500)*8
Packit 53d5b6
#    ... but this from Jean Delvare works better in pratice
Packit 53d5b6
    compute in3 (@ * 5.14) - 14.91, (@ + 14.91) / 5.14
Packit 53d5b6
    set in3_min -12*1.05
Packit 53d5b6
    set in3_max -12*0.95
Packit 53d5b6
# 0x15, DIMM
Packit 53d5b6
    label in4 "DIMM"
Packit 53d5b6
# 0x16, +3.3V
Packit 53d5b6
    label in5 "+3.3V"
Packit 53d5b6
    set in5_min 3.3*0.95
Packit 53d5b6
    set in5_max 3.3*1.05
Packit 53d5b6
# 0x17, +12V
Packit 53d5b6
    label in6 "+12V"
Packit 53d5b6
    compute in6 @*12,@/12
Packit 53d5b6
    set in6_min 12*0.95
Packit 53d5b6
    set in6_max 12*1.05
Packit 53d5b6
# Ox18, +5V
Packit 53d5b6
    label in7 "+5V"
Packit 53d5b6
    compute in7 @-0.15,@+0.15
Packit 53d5b6
    set in7_min 5*0.95
Packit 53d5b6
    set in7_max 5*1.05
Packit 53d5b6
# 0x19, 5VSB
Packit 53d5b6
    label in8 "5VSB"
Packit 53d5b6
    compute in8 @-0.15,@+0.15
Packit 53d5b6
    set in8_min 5*0.95
Packit 53d5b6
    set in8_max 5*1.05
Packit 53d5b6
# 0x1a, Battery Voltage
Packit 53d5b6
    label in9 "VBAT"
Packit 53d5b6
Packit 53d5b6
    label temp1 "CPU Temp"
Packit 53d5b6
    ignore temp2
Packit 53d5b6
    ignore temp3
Packit 53d5b6
    ignore temp4
Packit 53d5b6
    ignore temp5
Packit 53d5b6
    label temp6 "Sys Temp"
Packit 53d5b6
Packit 53d5b6
# 3 connected
Packit 53d5b6
# note that these fan labels are for a 1U rackmount and are given their
Packit 53d5b6
# positions based on where they are when you look at it from the front
Packit 53d5b6
# towards the back
Packit 53d5b6
#
Packit 53d5b6
# relabel them as necessary to however you have them set up
Packit 53d5b6
    label fan1 "Right Fan"
Packit 53d5b6
    ignore fan2
Packit 53d5b6
    ignore fan3
Packit 53d5b6
    ignore fan4
Packit 53d5b6
    label fan5 "Mid-right Fan"
Packit 53d5b6
    ignore fan6
Packit 53d5b6
    label fan7 "Middle Fan"
Packit 53d5b6
    ignore fan8
Packit 53d5b6
    ignore fan9
Packit 53d5b6
    ignore fan10
Packit 53d5b6
    ignore fan12
Packit 53d5b6
    ignore fan12
Packit 53d5b6
    # Override CPU temperature threshold
Packit 53d5b6
    set temp1_max       80
Packit 53d5b6
    set temp1_max_hyst  70
Packit 53d5b6
Packit 53d5b6
    set temp6_max       60
Packit 53d5b6
    set temp6_max_hyst  55
Packit 53d5b6
Packit 53d5b6
# NOTE: nearly everything on this chip is not used you can turn on alarms, if
Packit 53d5b6
# you have the appropriate setup for it and want to have chassis intrusion
Packit 53d5b6
# detection turned on
Packit 53d5b6
Packit 53d5b6
chip "w83627hf-*"
Packit 53d5b6
Packit 53d5b6
    ignore in0
Packit 53d5b6
    ignore in1
Packit 53d5b6
    ignore in2
Packit 53d5b6
    label in3 "+5.0V"
Packit 53d5b6
    compute in3 ((6.8/10)+1)*@ ,  @/((6.8/10)+1)
Packit 53d5b6
    ignore in4
Packit 53d5b6
    ignore in5
Packit 53d5b6
    ignore in6
Packit 53d5b6
    ignore in7
Packit 53d5b6
    ignore in8
Packit 53d5b6
    ignore fan1
Packit 53d5b6
    ignore fan2
Packit 53d5b6
    ignore fan3
Packit 53d5b6
    ignore alarms
Packit 53d5b6
    ignore temp1
Packit 53d5b6
    ignore temp2
Packit 53d5b6
    ignore temp3