Blame configs/Asus/Q1900-ITX.conf
|
Packit |
53d5b6 |
# Q1900 ITX Motherboard with a intel DTS Sensor, ITX format
|
|
Packit |
53d5b6 |
# 2018, by J. Schwender
|
|
Packit |
53d5b6 |
# dmi: Q1900-ITX
|
|
Packit |
53d5b6 |
# driver: nct6775
|
|
Packit |
53d5b6 |
#
|
|
Packit |
53d5b6 |
chip "soc_dts0-virtual-*"
|
|
Packit |
53d5b6 |
label temp1 "DTS 1"
|
|
Packit |
53d5b6 |
|
|
Packit |
53d5b6 |
chip "soc_dts1-virtual-*"
|
|
Packit |
53d5b6 |
label temp1 "DTS 2"
|
|
Packit |
53d5b6 |
|
|
Packit |
53d5b6 |
# ACPI thermal zone:
|
|
Packit |
53d5b6 |
chip "acpitz-virtual-*"
|
|
Packit |
53d5b6 |
label temp1 "CPU Socket"
|
|
Packit |
53d5b6 |
|
|
Packit |
53d5b6 |
# ADC has 8 mV conversion steps
|
|
Packit |
53d5b6 |
chip "nct6776-isa-*"
|
|
Packit |
53d5b6 |
label fan1 "System fan"
|
|
Packit |
53d5b6 |
ignore fan2
|
|
Packit |
53d5b6 |
ignore fan3
|
|
Packit |
53d5b6 |
ignore in4 # not shown in BIOS
|
|
Packit |
53d5b6 |
ignore in6 # not shown in BIOS
|
|
Packit |
53d5b6 |
ignore intrusion0
|
|
Packit |
53d5b6 |
ignore intrusion1
|
|
Packit |
53d5b6 |
ignore PCH_CHIP_TEMP
|
|
Packit |
53d5b6 |
# BIOS shows 24 mV steps in Readout for +5 V
|
|
Packit |
53d5b6 |
label in5 "+5 V"
|
|
Packit |
53d5b6 |
set in5_min 5 * 0.95
|
|
Packit |
53d5b6 |
set in5_max 5 * 1.05
|
|
Packit |
53d5b6 |
compute in5 @*3.00,@/3.00
|
|
Packit |
53d5b6 |
# BIOS shows 53 mV steps for 12 V
|
|
Packit |
53d5b6 |
label in1 "+12 V"
|
|
Packit |
53d5b6 |
set in1_min 12 * 0.95
|
|
Packit |
53d5b6 |
set in1_max 12 * 1.05
|
|
Packit |
53d5b6 |
compute in1 @*6.625,@/6.625
|
|
Packit |
53d5b6 |
|
|
Packit |
53d5b6 |
set in2_min 3.3 * 0.95
|
|
Packit |
53d5b6 |
set in2_max 3.3 * 1.05
|