Blame mibs/ietf/IANA-ITU-ALARM-TC-MIB

Packit 022b05
IANA-ITU-ALARM-TC-MIB DEFINITIONS ::= BEGIN
Packit 022b05
Packit 022b05
IMPORTS
Packit 022b05
   MODULE-IDENTITY, mib-2
Packit 022b05
       FROM SNMPv2-SMI          -- [RFC2578]
Packit 022b05
   TEXTUAL-CONVENTION
Packit 022b05
       FROM SNMPv2-TC;          -- [RFC2579]
Packit 022b05
Packit 022b05
Packit 022b05
Packit 022b05
 ianaItuAlarmNumbers MODULE-IDENTITY
Packit 022b05
     LAST-UPDATED "200409090000Z"  -- September 09, 2004
Packit 022b05
     ORGANIZATION "IANA"
Packit 022b05
     CONTACT-INFO
Packit 022b05
         "Postal:    Internet Assigned Numbers Authority
Packit 022b05
                     Internet Corporation for Assigned Names
Packit 022b05
                     and Numbers
Packit 022b05
                     4676 Admiralty Way, Suite 330
Packit 022b05
                     Marina del Rey, CA 90292-6601
Packit 022b05
                     USA
Packit 022b05
Packit 022b05
         Tel:    +1  310-823-9358
Packit 022b05
         E-Mail: iana@iana.org"
Packit 022b05
     DESCRIPTION
Packit 022b05
         "The MIB module defines the ITU Alarm
Packit 022b05
         textual convention for objects expected to require
Packit 022b05
         regular extension.
Packit 022b05
Packit 022b05
         Copyright (C) The Internet Society (2004).  The
Packit 022b05
         initial version of this MIB module was published
Packit 022b05
         in RFC 3877.  For full legal notices see the RFC
Packit 022b05
         itself.  Supplementary information may be available on:
Packit 022b05
         http://www.ietf.org/copyrights/ianamib.html"
Packit 022b05
      REVISION    "200409090000Z"  -- September 09, 2004
Packit 022b05
      DESCRIPTION
Packit 022b05
          "Initial version, published as RFC 3877."
Packit 022b05
     ::= { mib-2 119 }
Packit 022b05
Packit 022b05
IANAItuProbableCause ::= TEXTUAL-CONVENTION
Packit 022b05
    STATUS current
Packit 022b05
    DESCRIPTION
Packit 022b05
        "ITU-T probable cause values.  Duplicate values defined in
Packit 022b05
         X.733 are appended with X733 to ensure syntactic uniqueness.
Packit 022b05
         Probable cause value 0 is reserved for special purposes.
Packit 022b05
Packit 022b05
         The Internet Assigned Number Authority (IANA) is responsible
Packit 022b05
         for the assignment of the enumerations in this TC.
Packit 022b05
         IANAItuProbableCause value of 0 is reserved for special
Packit 022b05
         purposes and MUST NOT be assigned.
Packit 022b05
Packit 022b05
         Values of IANAItuProbableCause in the range 1 to 1023 are
Packit 022b05
         reserved for causes that correspond to ITU-T probable cause.
Packit 022b05
Packit 022b05
         All other requests for new causes will be handled on a
Packit 022b05
         first-come, first served basis and will be assigned
Packit 022b05
         enumeration values starting with 1025.
Packit 022b05
Packit 022b05
         Request should  come in the form of well-formed
Packit 022b05
Packit 022b05
Packit 022b05
         SMI [RFC2578] for enumeration names that are unique and
Packit 022b05
         sufficiently descriptive.
Packit 022b05
Packit 022b05
         While some effort will be taken to ensure that new probable
Packit 022b05
         causes do not conceptually duplicate existing probable
Packit 022b05
         causes it is acknowledged that the existence of conceptual
Packit 022b05
         duplicates in the starting probable cause list is an known
Packit 022b05
         industry reality.
Packit 022b05
Packit 022b05
         To aid IANA in the administration of probable cause names
Packit 022b05
         and values, the OPS Area Director will appoint one or more
Packit 022b05
         experts to help review requests.
Packit 022b05
Packit 022b05
         See http://www.iana.org"
Packit 022b05
    REFERENCE
Packit 022b05
        "ITU Recommendation M.3100, 'Generic Network Information
Packit 022b05
            Model', 1995
Packit 022b05
         ITU Recommendation X.733, 'Information Technology - Open
Packit 022b05
            Systems Interconnection - System Management: Alarm
Packit 022b05
            Reporting Function', 1992
Packit 022b05
         ITU Recommendation X.736, 'Information Technology - Open
Packit 022b05
            Systems Interconnection - System Management: Security
Packit 022b05
            Alarm Reporting Function', 1992"
Packit 022b05
Packit 022b05
    SYNTAX         INTEGER
Packit 022b05
            {
Packit 022b05
            -- The following probable causes were defined in M.3100
Packit 022b05
             aIS  (1),
Packit 022b05
             callSetUpFailure  (2),
Packit 022b05
             degradedSignal  (3),
Packit 022b05
             farEndReceiverFailure  (4),
Packit 022b05
             framingError  (5),
Packit 022b05
             lossOfFrame (6),
Packit 022b05
             lossOfPointer  (7),
Packit 022b05
             lossOfSignal  (8),
Packit 022b05
             payloadTypeMismatch (9),
Packit 022b05
             transmissionError (10),
Packit 022b05
             remoteAlarmInterface (11),
Packit 022b05
             excessiveBER  (12),
Packit 022b05
             pathTraceMismatch  (13),
Packit 022b05
             unavailable  (14),
Packit 022b05
             signalLabelMismatch (15),
Packit 022b05
             lossOfMultiFrame (16),
Packit 022b05
             receiveFailure (17),
Packit 022b05
             transmitFailure (18),
Packit 022b05
             modulationFailure (19),
Packit 022b05
             demodulationFailure (20),
Packit 022b05
             broadcastChannelFailure (21),
Packit 022b05
Packit 022b05
Packit 022b05
             connectionEstablishmentError (22),
Packit 022b05
             invalidMessageReceived (23),
Packit 022b05
             localNodeTransmissionError (24),
Packit 022b05
             remoteNodeTransmissionError (25),
Packit 022b05
             routingFailure (26),
Packit 022b05
Packit 022b05
 --Values 27-50 are reserved for communications alarm related
Packit 022b05
 --probable causes
Packit 022b05
 -- The following are used with equipment alarm.
Packit 022b05
Packit 022b05
             backplaneFailure (51),
Packit 022b05
             dataSetProblem  (52),
Packit 022b05
             equipmentIdentifierDuplication  (53),
Packit 022b05
             externalIFDeviceProblem  (54),
Packit 022b05
             lineCardProblem (55),
Packit 022b05
             multiplexerProblem  (56),
Packit 022b05
             nEIdentifierDuplication  (57),
Packit 022b05
             powerProblem  (58),
Packit 022b05
             processorProblem  (59),
Packit 022b05
             protectionPathFailure  (60),
Packit 022b05
             receiverFailure  (61),
Packit 022b05
             replaceableUnitMissing  (62),
Packit 022b05
             replaceableUnitTypeMismatch (63),
Packit 022b05
             synchronizationSourceMismatch  (64),
Packit 022b05
             terminalProblem   (65),
Packit 022b05
             timingProblem   (66),
Packit 022b05
             transmitterFailure  (67),
Packit 022b05
             trunkCardProblem  (68),
Packit 022b05
             replaceableUnitProblem  (69),
Packit 022b05
             realTimeClockFailure (70),
Packit 022b05
 --An equipment alarm to be issued if the system detects that the
Packit 022b05
 --real time clock has failed
Packit 022b05
             antennaFailure (71),
Packit 022b05
             batteryChargingFailure (72),
Packit 022b05
             diskFailure (73),
Packit 022b05
             frequencyHoppingFailure (74),
Packit 022b05
             iODeviceError (75),
Packit 022b05
             lossOfSynchronisation (76),
Packit 022b05
             lossOfRedundancy (77),
Packit 022b05
             powerSupplyFailure (78),
Packit 022b05
             signalQualityEvaluationFailure (79),
Packit 022b05
             tranceiverFailure (80),
Packit 022b05
             protectionMechanismFailure (81),
Packit 022b05
             protectingResourceFailure (82),
Packit 022b05
 -- Values 83-100 are reserved for equipment alarm related probable
Packit 022b05
 -- causes
Packit 022b05
 -- The following are used with environmental alarm.
Packit 022b05
             airCompressorFailure  (101),
Packit 022b05
Packit 022b05
Packit 022b05
             airConditioningFailure  (102),
Packit 022b05
             airDryerFailure   (103),
Packit 022b05
             batteryDischarging  (104),
Packit 022b05
             batteryFailure   (105),
Packit 022b05
             commercialPowerFailure  (106),
Packit 022b05
             coolingFanFailure  (107),
Packit 022b05
             engineFailure  (108),
Packit 022b05
             fireDetectorFailure  (109),
Packit 022b05
             fuseFailure  (110),
Packit 022b05
             generatorFailure  (111),
Packit 022b05
             lowBatteryThreshold (112),
Packit 022b05
             pumpFailure  (113),
Packit 022b05
             rectifierFailure  (114),
Packit 022b05
             rectifierHighVoltage  (115),
Packit 022b05
             rectifierLowFVoltage  (116),
Packit 022b05
             ventilationsSystemFailure  (117),
Packit 022b05
             enclosureDoorOpen  (118),
Packit 022b05
             explosiveGas  (119),
Packit 022b05
             fire (120),
Packit 022b05
             flood   (121),
Packit 022b05
             highHumidity  (122),
Packit 022b05
             highTemperature  (123),
Packit 022b05
             highWind  (124),
Packit 022b05
             iceBuildUp  (125),
Packit 022b05
             intrusionDetection  (126),
Packit 022b05
             lowFuel  (127),
Packit 022b05
             lowHumidity  (128),
Packit 022b05
             lowCablePressure  (129),
Packit 022b05
             lowTemperatue  (130),
Packit 022b05
             lowWater  (131),
Packit 022b05
             smoke  (132),
Packit 022b05
             toxicGas  (133),
Packit 022b05
             coolingSystemFailure (134),
Packit 022b05
             externalEquipmentFailure (135),
Packit 022b05
             externalPointFailure (136),
Packit 022b05
 -- Values 137-150 are reserved for environmental alarm related
Packit 022b05
 -- probable causes
Packit 022b05
 -- The following are used with Processing error alarm.
Packit 022b05
             storageCapacityProblem (151),
Packit 022b05
             memoryMismatch  (152),
Packit 022b05
             corruptData  (153),
Packit 022b05
             outOfCPUCycles   (154),
Packit 022b05
             sfwrEnvironmentProblem  (155),
Packit 022b05
             sfwrDownloadFailure  (156),
Packit 022b05
             lossOfRealTimel (157),
Packit 022b05
 --A processing error alarm to be issued after the system has
Packit 022b05
 --reinitialised.  This will indicate
Packit 022b05
 --to the management systems that the view they have of the managed
Packit 022b05
Packit 022b05
Packit 022b05
 --system may no longer
Packit 022b05
 --be valid.  Usage example: The managed
Packit 022b05
 --system issues this alarm after a reinitialization with severity
Packit 022b05
 --warning to inform the
Packit 022b05
 --management system about the event.  No clearing notification will
Packit 022b05
 --be sent.
Packit 022b05
             applicationSubsystemFailure (158),
Packit 022b05
             configurationOrCustomisationError (159),
Packit 022b05
             databaseInconsistency (160),
Packit 022b05
             fileError (161),
Packit 022b05
             outOfMemory (162),
Packit 022b05
             softwareError (163),
Packit 022b05
             timeoutExpired (164),
Packit 022b05
             underlayingResourceUnavailable (165),
Packit 022b05
             versionMismatch (166),
Packit 022b05
 --Values 168-200 are reserved for processing error alarm related
Packit 022b05
 -- probable causes.
Packit 022b05
             bandwidthReduced (201),
Packit 022b05
             congestion (202),
Packit 022b05
             excessiveErrorRate (203),
Packit 022b05
             excessiveResponseTime (204),
Packit 022b05
             excessiveRetransmissionRate (205),
Packit 022b05
             reducedLoggingCapability (206),
Packit 022b05
             systemResourcesOverload (207 ),
Packit 022b05
             -- The following were defined X.733
Packit 022b05
             adapterError (500),
Packit 022b05
             applicationSubsystemFailture (501),
Packit 022b05
             bandwidthReducedX733 (502),
Packit 022b05
             callEstablishmentError (503),
Packit 022b05
             communicationsProtocolError (504),
Packit 022b05
             communicationsSubsystemFailure (505),
Packit 022b05
             configurationOrCustomizationError (506),
Packit 022b05
             congestionX733 (507),
Packit 022b05
             coruptData (508),
Packit 022b05
             cpuCyclesLimitExceeded (509),
Packit 022b05
             dataSetOrModemError (510),
Packit 022b05
             degradedSignalX733 (511),
Packit 022b05
             dteDceInterfaceError (512),
Packit 022b05
             enclosureDoorOpenX733 (513),
Packit 022b05
             equipmentMalfunction (514),
Packit 022b05
             excessiveVibration (515),
Packit 022b05
             fileErrorX733 (516),
Packit 022b05
             fireDetected (517),
Packit 022b05
             framingErrorX733 (518),
Packit 022b05
             heatingVentCoolingSystemProblem (519),
Packit 022b05
             humidityUnacceptable (520),
Packit 022b05
             inputOutputDeviceError (521),
Packit 022b05
             inputDeviceError (522),
Packit 022b05
Packit 022b05
Packit 022b05
             lanError (523),
Packit 022b05
             leakDetected (524),
Packit 022b05
             localNodeTransmissionErrorX733 (525),
Packit 022b05
             lossOfFrameX733 (526),
Packit 022b05
             lossOfSignalX733 (527),
Packit 022b05
             materialSupplyExhausted (528),
Packit 022b05
             multiplexerProblemX733 (529),
Packit 022b05
             outOfMemoryX733 (530),
Packit 022b05
             ouputDeviceError (531),
Packit 022b05
             performanceDegraded (532),
Packit 022b05
             powerProblems (533),
Packit 022b05
             pressureUnacceptable (534),
Packit 022b05
             processorProblems (535),
Packit 022b05
             pumpFailureX733 (536),
Packit 022b05
             queueSizeExceeded (537),
Packit 022b05
             receiveFailureX733 (538),
Packit 022b05
             receiverFailureX733 (539),
Packit 022b05
             remoteNodeTransmissionErrorX733 (540),
Packit 022b05
             resourceAtOrNearingCapacity (541),
Packit 022b05
             responseTimeExecessive (542),
Packit 022b05
             retransmissionRateExcessive (543),
Packit 022b05
             softwareErrorX733 (544),
Packit 022b05
             softwareProgramAbnormallyTerminated (545),
Packit 022b05
             softwareProgramError (546),
Packit 022b05
             storageCapacityProblemX733 (547),
Packit 022b05
             temperatureUnacceptable (548),
Packit 022b05
             thresholdCrossed (549),
Packit 022b05
             timingProblemX733 (550),
Packit 022b05
             toxicLeakDetected (551),
Packit 022b05
             transmitFailureX733 (552),
Packit 022b05
             transmiterFailure (553),
Packit 022b05
             underlyingResourceUnavailable (554),
Packit 022b05
             versionMismatchX733 (555),
Packit 022b05
             -- The following are defined in X.736
Packit 022b05
             authenticationFailure (600),
Packit 022b05
             breachOfConfidentiality (601),
Packit 022b05
             cableTamper (602),
Packit 022b05
             delayedInformation (603),
Packit 022b05
             denialOfService (604),
Packit 022b05
             duplicateInformation (605),
Packit 022b05
             informationMissing (606),
Packit 022b05
             informationModificationDetected (607),
Packit 022b05
             informationOutOfSequence (608),
Packit 022b05
             keyExpired (609),
Packit 022b05
             nonRepudiationFailure (610),
Packit 022b05
             outOfHoursActivity (611),
Packit 022b05
             outOfService (612),
Packit 022b05
             proceduralError (613),
Packit 022b05
Packit 022b05
Packit 022b05
             unauthorizedAccessAttempt (614),
Packit 022b05
             unexpectedInformation (615),
Packit 022b05
Packit 022b05
             other (1024)
Packit 022b05
             }
Packit 022b05
Packit 022b05
IANAItuEventType ::= TEXTUAL-CONVENTION
Packit 022b05
    STATUS current
Packit 022b05
    DESCRIPTION
Packit 022b05
            "The ITU event Type values.
Packit 022b05
Packit 022b05
            The Internet Assigned Number Authority (IANA) is
Packit 022b05
            responsible for the assignment of the enumerations
Packit 022b05
            in this TC.
Packit 022b05
Packit 022b05
            Request should  come in the form of well-formed
Packit 022b05
            SMI [RFC2578] for enumeration names that are unique
Packit 022b05
            and sufficiently descriptive.
Packit 022b05
Packit 022b05
            See http://www.iana.org "
Packit 022b05
    REFERENCE
Packit 022b05
           "ITU Recommendation X.736, 'Information Technology - Open
Packit 022b05
            Systems Interconnection - System Management: Security
Packit 022b05
            Alarm Reporting Function', 1992"
Packit 022b05
    SYNTAX         INTEGER
Packit 022b05
           {
Packit 022b05
           other (1),
Packit 022b05
           communicationsAlarm (2),
Packit 022b05
           qualityOfServiceAlarm (3),
Packit 022b05
           processingErrorAlarm (4),
Packit 022b05
           equipmentAlarm (5),
Packit 022b05
           environmentalAlarm (6),
Packit 022b05
           integrityViolation (7),
Packit 022b05
           operationalViolation (8),
Packit 022b05
           physicalViolation (9),
Packit 022b05
           securityServiceOrMechanismViolation (10),
Packit 022b05
           timeDomainViolation (11)
Packit 022b05
           }
Packit 022b05
Packit 022b05
END